Mouthpiece, Disposable, For a more sterile environment, use the cardboard mouthpieces to help eliminate the spreading of contagious material between students
Helmholtz Coil, Specifications: Coil diameter: 295 mm Coil spacing: 150 mm Number of turns per coil: 124 Enamelled copper wire thickness: 1.5 mm DC resistance: 1.2 Ohms each Maximum coil current: 5 A Maximum coil voltage: 6 V Maximum flux density at 5 A: 3.7 mT
Boyle's law Horizontal apparatus, A horizontally mounted acrylic tube having a graduated scale (0-300cm3) along one side. A gas tap closes the tube. Pressure gauge is present next to gas tap.
Plastic Beaker, Square Ratio Graduated, with Printed Graduations, polypropylene, 1000mL, Subdivisions: 100mL, Printed in blue, Graduated square ratio beaker, Stackable
Sonometer Wire, 1.3lbs, 9.8x6.7x6.3inch, Set of six wires, brass and steel, length 1.5 m, Set of six wires, brass and steel, length 1.5 m of 22, 24, 26 SWG. Ends looped ready for use.
Sterile. Individually packaged in soft pouch. WxL: 7.6cmx3.7m. One-ply cotton/polyester blend crocheted bandage is ideal for securing dressings, I.V.s, and splints. Holds securely to any body contour, allowing for movement and some soft tissue swelling. Highly absorbent.
Sterile. Individually packaged in soft pouch. WxL: 10.2cmx3.7m. One-ply cotton/polyester blend crocheted bandage is ideal for securing dressings, I.V.s, and splints. Holds securely to any body contour, allowing for movement and some soft tissue swelling. Highly absorbent.
Synthesis of Aspirin, Includes:2x25 ml Acetic Anhydride UN1715, 1x15 g Salicylic Acid, 2x25 ml Sulfuric Acid Concentrate UN1830, 2x25 ml Toluene UN1294, The exothermic reaction willcause the temperature to increase to 70-80C
Digital, microprocessor controlled dry bath with two independently controlled blocks. Removable hinged lid features a dividing wall to prevent air transfer between the chambers. Control panel features large digital displays for each block. two isolated chambers.
Independence of Motion, enables the Projectile Launcher to perform the classic experiment where one ball is dropped as another is projected horizontally. The balls strike the floor simultaneously. A built-in level makes leveling th
Axle for investigating rotational oscillation of various test bodies and for determining their moments of inertia from the period of oscillation. With ball-bearing mounted shaft, coil spring and holding lug.
Green Diffraction Laser, optional accessory for the Diffraction Apparatus, Operating at 532 nm, it allows students to see and measure how diffraction patterns depend on light wavelength