Dynamics Cart and Track System with Go Direct* Sensor Cart, for College and High School, completely wireless system simplifies experiment setup & allows basic experiments to be conducted with/without the track, Position resolution: 0.25mm, Track length: 1.2 m
Go Direct* ORP (Oxidation-Reduction Potential) Sensor, measures the ability of a solution to act as an oxidizing or reducing agent, Type: Sealed, gel-filled, epoxy body, Ag/AgCl reference, Storage solution: pH-4/KCl solution, Temperature range: 0 to 60 degree 'C, 12 mm OD
Go Direct* Wide-Range Temperature Probe, with Micro USB Cable, -20degC to 330degC Temperature, Temperature sensing element Platinum RTD (100 omega), Maximum temperature that the sensor can tolerate without damage 380degC, Dimension: 28x17 cm
Go Direct* Radiation Monitor, detects alpha, beta, gamma, and X-ray radiation, Sensor: LND 712 (or equivalent) halogen-quenched GM tube with a mica end window, 1.5 to 2.0 mg/cm2 thick, Red LED blinks on radiation detection, Optional audio signal on radiation detection
Go Direct* Motion Detector, uses ultrasound to measure the position, velocity, and acceleration of moving objects, Maximum data collection rate: 30 samples/s, Distances measured from 15 cm to 2.5 m, Temperature compensated, 1/4-20 threaded hole, 1.5 m USB cable
Voltage Probe, This sensor is used to measure voltages in the range of -30 to +30 voltsUse this sensor in experiments that involve voltages larger than 10 volts, such as when working with large solar panels. Since this voltage probe covers
Go Direct* Current Probe User Manual, Probe range: +/-1 A and +/-0.1 A, 300 mA Li-Poly Battery, 24 hours Battery life, 500 full charge cycles (several years depending on usage) Battery life (long term), 1.5 A and 0.5 A non-damaging current, volt: +/-10 V
Go Direct* pH Sensor, is a general-purpose pH sensor used to monitor pH of aqueous solutions, pH range: 0-14, Type: Sealed, gel-filled, epoxy body, Ag/AgCl reference, Shaft diameter: 12 mm OD, Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution)
Go Direct* Gas Pressure Sensor, measures the absolute pressure of a gas, Specifications: Range: 0 to 400 kPa, Resolution: 0.03 kPa, Maximum pressure that the sensor can tolerate without permanent damage: 450 kPa, Connections: Wireless Bluetooth, Wired USB
Go Direct* Sensor Cart, Green, for College, High School, and Middle School Science, features built-in, wireless sensors for one-dimensional dynamics and kinematics experiments, directly connects wirelessly via Bluetooth, Position resolution: 0.25 mm